III. PRINCIPLE OF OPERATION
A. General:
1. Movement occurs as pressure variations reg-
is ter on the diaphragm. The registering pres-
sure is the inlet, P
1
or upstream pressure. The
range spring opposes diaphragm movement.
SECTION III
As the inlet pressure drops, the range spring
pushes the diaphragm down, closing the port;
as inlet pressure increases, the diaphragm
pushes up and the port opens.
2. A complete diaphragm failure may cause the
regulator to fail close, and process uid will
discharge from the spring chamber vent hole.
CAUTION
SECTION II
II. INSTALLATION
A. General:
1. A diaphragm valve should be installed up-
stream of the regulator.
2. An inlet pressure gauge should be located
ap prox i mate ly ten pipe diameters upstream
and within sight.
3. All installations should include an upstream
relief device if the inlet pressure could exceed
the pressure rating of any equip ment or the
maximum inlet pressure rating of the unit.
4. Flow Direction: Install so ow enters through
the side connection and exits the bottom con-
nection.
5. Install with spring chamber (2) in the vertical
up po si tion to allow for proper draining.
I. DESCRIPTION AND SCOPE
Model C-BPV is a self-contained back pressure / relief regulator utilized in sanitary biotechnological process piping
systems and is used to control upstream (inlet or P
1
) pressure. Inlet and outlet sizes are 3/4", 1", 1-1/2", 2" and 3".
This angle style regulator is only suit able for liquids and gases at temperatures less than 300°F (149°C). Refer to
Technical Bulletin C-BPV-TB for speci c design con di tions.
SECTION l
MODEL C-BPV
BACK PRESSURE / RELIEF REG U LA TOR
IOM-C-BPV
12-13
INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM)
CAUTION
This is not a safety device and must not be substituted for a code approved pressure safety relief valve or a rupture disc.
CAUTION
Installation of adequate overpressure pro tec tion is recom-
mended to pro tect the reg u la tor from overpressure and
all down stream equip ment from damage in the event of
regulator failure.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - MODEL C-BPV

III. PRINCIPLE OF OPERATIONA. General:1. Movement occurs as pressure variations reg- is ter on the diaphragm. The registering pres- sure is the inle

Page 2 - CAUTION

IOM-C-BPV10 Item No. Description 1 Body 2 Spring Chamber 3 Pressure Plate 4 Spring Button 5 Adjusting Screw 5.1 Adjusting Screw Cap 5.2 Pi

Page 3

IOM-C-BPV11 Item No. Description 1 Body 2 Spring Chamber 3 Pressure Plate 4 Spring Button 5 Adjusting Screw 5.1 Adjusting Screw Cap 5.2 Pi

Page 4

Cashco, Inc.P.O. Box 6 Ellsworth, KS 67439-0006PH (785) 472-4461Fax. # (785) 472-3539www.cashco.comemail: [email protected] in U.S.A. IOM-C-BP

Page 5

IOM-C-BPV22. If the regulator and system are both to be shut- down, slowly close the inlet (up stream) block valve.SECTION IVIV. START-UPA. General:1

Page 6 - SECTION VII

IOM-C-BPV32. Ensure that the lever (16) is in standard horizontal position. Relax range spring (7) by turning adjustment nut (6) or han dle (36) CCW

Page 7 - SECTION VIII

IOM-C-BPV4a. Remove set screw (37) from guide post assembly (22).b. Rotate guide post (22) CCW and remove from plug (18).c. Turn adapter (20) CCW a

Page 8 - IOM-C-BPV8

IOM-C-BPV510C. For Sizes 3/4"- 1-1/2 w/65-125 psig range spring: Clamp the plug (18) at the fl ats on the plug in a smooth jawed vice.a. Remov

Page 9 - IOM-C-BPV

IOM-C-BPV6Figure 2: Spring Chamber in Lock-Open Position. CAUTIONOwner’s cleaning solution must be compatible with regu-lator’s trim materia

Page 10

IOM-C-BPV7SECTION VIIINEW REPLACEMENT UNIT:Contact your local Cashco, Inc., Sales Rep re- sen ta tive with the Serial Number and Product code. With t

Page 11

IOM-C-BPV8NOTES

Page 12

IOM-C-BPV9NOTES