INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM)
IOM-DA5
11/13
I. DESCRIPTION AND SCOPE
The Model DA5 is a spring operated back pressure regulator used to control upstream (inlet or P1) pressure. Sizes
are 1/2" (DN15), 3/4" (DN20), 1" (DN25), 1 1/4" (DN32), 1 1/2" (DN40), 2" (DN50), 2 1/2" (DN65), 3" (DN80) and
4" (DN100). With proper trim uti li za tion, the unit is suitable for liquid, gaseous, or steam service. The Model DA5
is available in a more common “reverse” ow direction arrangement, that is balanced against outlet pressure varia-
tions, and a “standard” ow direction arrangement that is unbalanced. Refer to Technical Bulletin DA5-TB for design
conditions and selection rec om men da tions. (NOTE: This product was formerly iden ti ed as a Model D5 or Type V;
a Model DA5, D5 and Type V are one and the same product.)
MODEL DA5
DA5 - DIRECT-ACTING, SPRING LOADED
BACK PRESSURE REGULATOR
SECTION I
II. REFERENCES
Refer to Technical Bulletin DA5-TB and DAG-TB for
tech ni cal speci cations of a Model DA5 regulator.
ABBREVIATIONS
CCW – Counter Clockwise
CW – Clockwise
ITA Inner Trim Assembly
III. INSTALLATION
4. Install block valves and pressure gauges to pro-
vide means for adjustment, operation, bypass,
or removal of the regulator. A pipeline strainer is
recommended upstream of inlet port to remove
typical pipe line debris from entering valve and
damaging internal “soft goods”, primarily the dy-
namic side seal and V-TFE seat when applied.
5. Upstream Sensing Installation Considerations
– Internal or External Sensing:
a. The regulator may be installed with internal
or external sensing. Unless otherwise spec-
i ed, the regulator is supplied by the factory
with internal sensing. The regulator may be
con vert ed in the eld to external sensing. (See
Section VII maintenance, Part H – Converting
Internal/External Sensing.
b. Reference DAG-TB, Table DAG-12 for rec-
om men da tions for applying external pressure
sensing.
c. For internal sensing, no external line is re-
quired. For external sensing, use an external
control line. The line is connected from the
port 1/4" (DN8) NPT on the side of the body
di a phragm ange (see following schematic)
to a pressure tap upstream of the regulator.
SECTION III
SECTION II
CAUTION
For welded installations, all internal trim parts, seals and
diaphragm(s) must be removed from reg u la tor body prior to
welding into pipeline. The heat of fusion welding will dam-
age non-metallic parts if not re moved. NOTE: This does
not apply to units equipped with extended pipe nip ples.
1. Install per direction of ow arrow indicated on body,
or "IN" and "OUT" markings.
2. Regulator may be rotated around pipe axis 360
degrees. For ease of maintenance, the rec om -
mend ed position is with the spring chamber (4)
upwards. In liquid service it is recommended that
the spring cham ber be oriented down wards, and
that a cus tom er supplied and installed vent valve
be pro vid ed at the external sensing connection
to bleed-off trapped gas/air under the diaphragm
during initial startup.
3. Provide space below, above, and around reg u la tor
for removal of parts during maintenance.
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - MODEL DA5

INSTALLATION, OPERATION & MAINTENANCE MANUAL (IOM) IOM-DA511/13I. DESCRIPTION AND SCOPEThe Model DA5 is a spring operated back pressure regul

Page 2 - CAUTION

IOM-DA510of range spring is less than 55 psig, use test pressure of 5 psig less than upper value of range spring. If upper value of range spring is gr

Page 3 - SECTION VI

IOM-DA5 113. Upstream pressure too high.Possible Causes RemediesA. Debris in trim preventing movement. A. Clean unit of debris.B. Undersized regulato

Page 4 - (FTC Flow Direction Only)

IOM-DA512SECTION IXNEW REPLACEMENT UNIT:Contact your local Cashco, Inc., Sales Rep re sen- ta tive with the Serial Number and Product code. With this

Page 5 - WARNING

IOM-DA5 13 Item No. Description 1 Adjusting Screw 2 Adjusting Screw Lock Nut 4 Spring Chamber 5 Spring Follower (Button) 6 Range Spring

Page 6

IOM-DA514 Item No. Description 1 Adjusting Screw 2 Adjusting Screw Lock Nut 4 Spring Chamber 5 Spring Follower (Button) 6 Range Spring

Page 7

IOM-DA5 15The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accurac

Page 8

Cashco, Inc.P.O. Box 6 Ellsworth, KS 67439-0006PH (785) 472-4461Fax. # (785) 472-3539www.cashco.comemail: [email protected] in U.S.A. DA5-IOMC

Page 9

IOM-DA52A tubing outside diameter of 0.25 inch is adequate for short sensing lines (less than 4 feet). Use 3/8" tubing or 1/4" schedule 40

Page 10 - SECTION VIII

IOM-DA5 39. Reduce system fl ow to a minimum level and ob-serve pressure set point. Inlet pressure will de-crease from the set point of Step 8. The m

Page 11

IOM-DA54Figure 1: Dynamic Side Seals(FTC Flow Direction Only)

Page 12 - CAUTION

IOM-DA5 5B. Main Valve Disassembly:1. Shut down the system in accordance with Section VI. 2. Disconnect the external sensing line, if in- stalled.3

Page 13 - FTO – Flow To Open

IOM-DA56Re move di a phragm lock nut (7) after fully loosened and socket wrench is removed.c. Remove upper diaphragm pressure plate (8).d. Remove di

Page 14

IOM-DA5 7vise and rotate end-for-end and resecure in vise using same metal bars.5. Body Sizes 2-1/2" thru 4":a. Orient plug (20) with thre

Page 15 - IOM-DA5 15

IOM-DA58be on upper side, “fl at” side down wards. For metal diaphragm construction the “rounded” surface of the lower diaphragm push er plate (10) sho

Page 16

IOM-DA5 9circumferentially press the fi rst (low er) piston ring seal (27.5) inwards into the valve plug (20) groove until the fi rst piston ring seal

Comments to this Manuals